| ردیف |
کد |
توضیحات فنی |
| 1 |
7SJ8031-5EB00-1FC0 |
OVERCURRENT PROTECTION RELAYHOUSING 1/6 19″, 4 X I, 3 X U,3 BI, 5 BO, (2 CHANGEOVER) 1LIVE STATUS CONTACTMEASURING INPUTS:IPH = 1A / 5A, IE = 1A / 5ARATED AUXILIARY VOLTAGEDC 60V/ 110V / 125V/ 220V,AC 115V/ 230VFLUSH-MOUNTING CASE,SCREW-TYPE TERMINALREGION WORLD, IEC/ANSI,LANGUAGE ENGLISH(LANGUAGE CHANGEABLE)STANDARD FRONTNO SYSTEM PORTNO SYSTEM PORT AMETERING: FAULT RECORDINGFUNCTIONALITY:TOC+ PHASEOVERCURRENT (50/51)I>,I>>,I>>>,IP, TIMEOVERCURR.PROTECTION GROUND50N/51N,IE>,IE>>, IE>>>,IEPGROUND FAULT PROTECTION IEE>,IEE>>, IEEP OVERLOAD PROTECTION(49) TRIP CIRCUIT SUPERVISION(74TC) CIRCUIT BREAKER FAILUREPROTECT NEGATIVE SEQUENCEPROTECTION UNDERCURRENTMONITORING (37) LOCK OUT (86)ADDITIONAL FUNCTIONS:DRIECTIONAL PHASE & GROUNDOVERCURRENT DIRECT. SENSITIVEGROUND FAULT VOLTAGE A.FREQUENCY PROTECTION FLEXIBLEPROTECTION FUNCTIONS (CURRENTAND VOLTAGE PARAMET.)WITHOUT AUTO-RECLOSUREWITHOUT FAULT LOCATOR |
| 2 |
7UT6131-4EB02-1BC0 |
DIGITAL DIFFERENTIAL PROTECTIONRELAY, FOR TRANSFORMER,GENERATORS, MOTOR, SMALLBUSBARS AND SHORT CABLE, 4-LINEALPHANUM.BACKLIT DISPLAY 14PROGRAMMABLE LED, NAVIGATIONKEYS, FUNCTION KEYS, NUMBERBLOCK, CASE 1/2 X 19″, 5BI, 8BO, 1 WATCHDOG CONTACT, 11I,IEE,CURRENT TRANSFORMER: 1ASUPPLY VOLTAGE: DC 60V TO 125V,TRIGGER LEVEL BINARY INPUT 19VFLUSH MOUNTING CASE,SCREW TERMINALS(DIRECT WIRING/RING LUGS)REGION WORLD, IEC/ANSI,LANGUAGE ENGLISH(LANGUAGE CHANGEABLE)NO SYSTEM PORTDIGSI 4/MODEM PORT(ON REAR OF DEVICE) PORT CDIGSI 4, BROWSER OR THERMO-BOX,ELECTRICAL RS485BASIS MEASURED VALUES,FAULT RECORDINGRESTRICTED EARTH FAULT LOWIMPEDANCE (87N) UMZ -1-PHASEFOR RESTRICTED EARTH FAULT HIGHIMPEDANCE (87N W/O RESISTOR ANDVARISTOR) SENSITIVEOVERCURR.-TIME PROT./ TANKPROTECTION (64) NEGATIVESEQUENCE PROTECT. (46) BREAKERFAILURE PROTECT. (50BF) TRIPCIRCUIT SUPERVISION (74TC)ADDITIONAL FUNCTION: VOLTGAEMEASUREMENT AND OVEREXCITATIONPROTECTION, OVER-/UNDERVOLTAGEPROTECTION, FREQUENCYPROTECTION, DIRECTIONALPROTECTION, FUSE FAILUREMONITORWITHOUT ADDITIONAL FUNCTIONS |
| 3 |
7SJ8012-5EB00-1FA0 |
OVERCURRENT PROTECTION RELAYHOUSING 1/6 19″, 4 X I, 3 BI, 5BO, (2 CHANGEOVER) 1 LIVESTATUS CONTACTMEASURING INPUTS:IPH = 1A / 5A,IEE (SENSITIVE) =0,001 TO 1,6 A/ 0,005 TO 8ARATED AUXILIARY VOLTAGEDC 60V/ 110V / 125V/ 220V,AC 115V/ 230VFLUSH-MOUNTING CASE, SCREW-TYPE TERMINALREGION WORLD, IEC/ANSI,LANGUAGE ENGLISH(LANGUAGE CHANGEABLE)STANDARD FRONTNO SYSTEM PORTNO SYSTEM PORT AMETERING: FAULT RECORDINGFUNCTIONALITY: TOC+PHASE OVERCURRENT (50/51)I>,I>>,I>>>,IP,TIME OVERCURR.PROTECTION GROUND50N/51N, IE>, IE>>,IE>>>, IEPGROUND FAULT PROTECTIONIEE>.IEE>>,IEEPOVERLOAD PROTECTION (49)TRIP CIRCUIT SUPERVISION (74TC)CIRCUIT BREAKER FAILURE PROTECTNEGATIVE SEQUENCE PROTECTIONUNDERCURRENT MONITORING (37)LOCK OUT (86)PARAMETER CHANGEOVERMONITORING FUNCTIONSCONTROL OF CIRCUIT BREAKERFLEXIBLE PROTECTION FUNCTIONS(CURRENT PARAMETERS)INRUSH RESTRAINTWITHOUT AUTO-RECLOSUREWITHOUT FAULT LOCATOR |
| 4 |
7SJ6022-4EB00-1FJ0 |
NUMERICAL OVERCURRENT-TIMEPROTECT. RELAY SIPROTEC 7SJ602OPTIONAL: MOTOR PROTECTIONOPTIONAL: COMMUNICATIONINTERFACE BINARY INPUTVOLTAGE:24 TO 250V MEASURINGINPUTS (1 X V,3 X I): IPH = 1A,IE = SENSITIVE (IEE = 0.003 TO1.5A)SUPPLY VOLTAGE: DC 48 TO 125VTRIGGER LEVEL BINARY INPUT 19VFLUSH MOUNTING, SCREW TERMINALS(DIRECT WIRING/RING LUGS)LANGUAGE ENGLISCH, GERMAN,FRENCH, SPANISH, 50/60HZIEC/ANSI, REGION WORLDWITHOUT SYSTEM INTERFACEWITHOUT COMMANDWITH FAULT RECORDING FUNCTIONALITY: TOC+PHASE OVERCURRENT (50/51)I>,I>>,IP,REVERSE INTERLOCKING,INDEPENDENT OF PHASE ROTATIONGROUND OVERCURRENT (50N/51N)IE>, IE>>, IEP,OVERLOAD PROTEC.WITH 2 TIME CONSTANTS (49)TRIP CIRCUIT SUPERVISION (74TC)BREAKER-FAILURE PROTECT. (50BF)COLD LOAD PICKUP,NEGATIVE SEQUENCE (46)SENSITIVE GROUND/EARTH-FAULTDETECTION IEE>, IEE>>, IEP,VOLTAGE AND POWER MEASURINGWITHOUT AUTOMATIC RECLOSING |
| 5 |
7RW6000-4EA00-0DP4 |
NUMERICAL VOLTAGE,FREQUENCY ANDOVEREXCITATION RELAY BINARYINPUT VOLTAGE 24 TO 250V WITHSERIAL RS 485-INTERFACERATED AUXILIARY VOLTAGE60/110/125V DCIN 7XP20 CASEFOR PANEL FLUSH MOUNTINGOR FOR CUBICLE MOUNTINGPRESETTING OF LANGUAGEENGLISHSCOPE OF FUNCTIONS:VOLTAGE A. FREQUENCY PROTECTION |
| 6 |
7SA6111-4AB02-0GP4 |
DISTANCE PROTECTION RELAY 7SA61OPERATOR PANEL WITH: 4-LINEBACK-LIT DISPLAY, FUNCTIONKEYS,NUMERICAL KEYS,PC-INTERFACE, EARTH-FAULT PROT.DIRECTIONAL, EARTHED NETWORKSMEASURING INPUT (4 X V, 4 X I)IPH = 1A, IE = 1A (MIN = 0.05A)AUXILIARY VOLTAGE:60 TO 125V DC,BINARY INPUT THRESHOLD 19VHOUSING WIDTH 1/2 19″, 14 LEDS13 BINARY/INDICATION INPUTS,5 SIGNAL/COMMAND OUTPUTS,12 FAST RELAYSFLUSH MOUNTING HOUSING/SCREW TERMINALSREGION WORLD, LANGUAGE ENGLISH(SELECTABLE)PORT B: NONE PORT C:DIGSI/MODEM, ELECTRIC RS485,TRIPPING 3-POLE,DISTANCE PROTECTION STARTING:Z<(POLYGON),V/PHI, POWERSWING DETECTION,AUTO-RECLOSURE, SYNCHRO-CHECK,VOLTAGE PROTECTION V>/V<, |
| 7 |
7SJ8041-5EB00-1FC0 |
OVERCURRENT PROTECTION RELAYHOUSING 1/6 19″, 4 X I, 3 X U,7 BI, 8 BO, (2 CHANGEOVER) 1LIVE STATUS CONTACTMEASURING INPUTS:IPH = 1A / 5A, IE = 1A / 5ARATED AUXILIARY VOLTAGEDC 60V/ 110V / 125V/ 220V,AC 115V/ 230VFLUSH-MOUNTING CASE,SCREW-TYPE TERMINALREGION WORLD, IEC/ANSI,LANGUAGE ENGLISH(LANGUAGE CHANGEABLE)STANDARD FRONTNO SYSTEM PORTNO SYSTEM PORT AMETERING: FAULT RECORDINGFUNCTIONALITY:TOC+ PHASEOVERCURRENT (50/51)I>,I>>,I>>>,IP, TIMEOVERCURR.PROTECTION GROUND50N/51N,IE>,IE>>, IE>>>,IEPGROUND FAULT PROTECTION IEE>,IEE>>, IEEP OVERLOAD PROTECTION(49) TRIP CIRCUIT SUPERVISION(74TC) CIRCUIT BREAKER FAILUREPROTECT NEGATIVE SEQUENCEPROTECTION UNDERCURRENTMONITORING (37) LOCK OUT (86)ADDITIONAL FUNCTIONS:DRIECTIONAL PHASE & GROUNDOVERCURRENT DIRECT. SENSITIVEGROUND FAULT VOLTAGE A.FREQUENCY PROTECTION FLEXIBLEPROTECTION FUNCTIONS (CURRENTAND VOLTAGE PARAMET.)WITHOUT AUTO-RECLOSUREWITHOUT FAULT LOCATOR |
| 8 |
7SJ8021-5EB00-1FA0 |
OVERCURRENT PROTECTION RELAY HOUSING 1/6 19″, 4 X I, 7 BI, 8BO, (2 CHANGEOVER) 1 LIVESTATUS CONTACTMEASURING INPUTS:IPH = 1A / 5A, IE = 1A / 5ARATED AUXILIARY VOLTAGEDC 60V/ 110V / 125V/ 220V,AC 115V/ 230VFLUSH-MOUNTING CASE,SCREW-TYPE TERMINALREGION WORLD, IEC/ANSI,LANGUAGE ENGLISH(LANGUAGE CHANGEABLE)STANDARD FRONTNO SYSTEM PORTNO SYSTEM PORT AMETERING: FAULT RECORDINGFUNCTIONALITY: TOC+PHASE OVERCURRENT (50/51)I>,I>>,I>>>,IP,TIME OVERCURR.PROTECTION GROUND50N/51N, IE>, IE>>,IE>>>, IEPGROUND FAULT PROTECTIONIEE>.IEE>>,IEEPOVERLOAD PROTECTION (49)TRIP CIRCUIT SUPERVISION (74TC)CIRCUIT BREAKER FAILURE PROTECTNEGATIVE SEQUENCE PROTECTIONUNDERCURRENT MONITORING (37)LOCK OUT (86)PARAMETER CHANGEOVERMONITORING FUNCTIONSCONTROL OF CIRCUIT BREAKERFLEXIBLE PROTECTION FUNCTIONS(CURRENT PARAMETERS)INRUSH RESTRAINTWITHOUT AUTO-RECLOSUREWITHOUT FAULT LOCATOR |
| 9 |
7SA6121-4BB02-4PP4 |
DISTANCE PROTECTION RELAY 7SA61OPERATOR PANEL WITH: 4-LINEBACK-LIT DISPLAY, FUNCTIONKEYS,NUMERICAL KEYS,PC-INTERFACE, EARTH-FAULT PROT.DIRECTIONAL, EARTHED NETWORKSMEASURING INPUT (4 X V, 4 X I)IPH = 1A, IE = 1A (MIN = 0.05A)AUXILIARY VOLTAGE:60 TO 125V DC, BINARY INPUT THRESHOLD 19VHOUSING WIDTH 1/1 19″, 14 LEDS29 BINARY/INDICATION INPUTS, 21SIGNAL/COMMAND OUTPUTS, 12 FASTRELAYS, FLUSH MOUNTING HOUSING/SCREW TERMINALSREGION WORLD, LANGUAGE ENGLISH(SELECTABLE)PORT B: NONEPORT C:DIGSI/MODEM, ELECTRIC RS485,TRIPPING 1/3-POLE,DISTANCE PROTECTION STARTING:Z<(POLYGON),V/PHI, POWERSWING DETECTION, PARALLEL LINECOMPENSATION,AUTO-RECLOSURE, SYNCHRO-CHECK,VOLTAGE PROTECTION V>/V<, |
| 10 |
7SA5221-4DB00-4QP4 |
FULL SCHEME DISTANCE PROTECTIONRELAY, CURRENT TRANSFORMER:PHASE=1A,GROUND=1A (MIN=0,05A)FLUSH-MOUNTG. HOUSING 1/1 X 19″24 BI, 32 BOAUXIL. VOLTAGE: 60VTO 125V DCBINARY INPUT THRESHOLD 19VREGION WORLD,LANGUA. UK-ENGLISH(LANGUAGE SELECTABLE)WITHOUT SYSTEM INTERFACENO 2ND OPERATING INTERFACEFUNCTION 1: TRIP MODE 1-AND3-POLEFUNCTION 2: DISTANCECHARACTERISTIC Z<,QUADRILATERAL AND/OR MHO WITHPOWERSWING WITH PARALLEL LINECOMPENSATIONFUNCTION 3: WITH AUTORECLOSUREWITH SYNCHROCHECK W/O BREAKERFAILURE PROTECTION WITHOVERVOLTAGE PROTECTIONFUNCTION 4: WITH GROUND FAULTOVERCURRENT PROTECTION |
| 11 |
7VH6001-0EA10-0AA0 |
ANALOG SINGLE-PHASE HIGHIMPEDANCE DIFFERENT. RELAYBINARY INPUT VOLTAGE:24 TO 250VFOR RESET OF LOCKOUT PICKUPVOLTAGE SETTABLE VIA RESISTORSWITH VARISTOR UP TO 125 VEFF: 600A/1S/S256WITH INTEGRATED CONVERTER:24V TO 250V DC, 80V TO 264V ACIN HOUSING 7XP20FOR PANEL FLUSH MOUNTING ORCUBICLE MOUNTING(WITH TERMINALS AT THE BACK)MAX. PICKUP VOLTAGE 60V(STEPS OF 6V)LOCKOUT OF TRIP COMMAND |
| 12 |
7SS5220-4AB02-1BA0 |
DISTRIBUTED BUSBAR/ CIRCUITBREAKER FAILURE PROTECT. 7SS52CENTRAL UNIT, 50/60HZ, FIRMWAREVERSION: V4RATED AUXILIARY VOLTAGE:DC 110V TO 125VIN SUBRACK ES902CREGION WORLD, LANGUAGE: ENGLISH(LANGUAGE CHANGEABLE)WITHOUT SYSTEM INTERFACESERVICE INTERFACE: DIGSI 4,ELECTRICAL RS485WITHOUT ADDITIONAL FUNCTIONEQUIPPED FOR 16 BAYS |
| 13 |
7SS5251-5FA01-0AA2 |
DISTRIBUTED BUSBAR/ CIRCUITBREAKER FAILURE PROTECT. 7SS52BAY UNIT, 1/3 X 19″, 50/60HZ,10 BI, 5CR, 2AR, 3 LED,FIRMWARE VERSION: V3 SUPPLYVOLTAGE: 48 -250V DC CASE FORPANEL FLUSH MOUNTING/ CUBICLEMOUNTING, WITHOUT GLASS PANERATED CURRENT: 1AWITHOUT OVERCURR.-TIME PROTECT. |
| 14 |
7PA2732-0AA00-1 |
FAST TRIP RELAY 4 CHANGE OVERCONTACTS OPERATING TIME 8MSAUXILIARY VOLTAGE: 110/125V DCRELAIS WITH SOCKET 7XP9011-2FOR FLUSH MOUNTING |
| 15 |
7PA3032-1AA00-1 |
TRIP CIRCUIT SUPERVISION RELAYSINGLE PHASE AUXILIARY VOLTAGE:110/125V DCRELAIS WITH SOCKET 7XP9011-0FOR FLUSH MOUNTING |
| 16 |
7PA2131-1 |
FAST LOCK-OUT RELAY 4 CHANGEOVER CONTACTS OPERATING TIME8MS AUXILIARY VOLTAGE: 110V DC WITH RESET PUSHBUTTONRELAIS WITH SOCKET 7XP9011-1FOR FLUSH MOUNTING |